GeekTechReview
Menu

Disclosure: we currently have no affiliate relationships, and no link on this site earns us a commission. Details

Methodology

GeekTechReview is a data site. We do not test products and we do not publish reviews or ratings. This page explains where every number on the site comes from.

Coverage

The table currently covers 86 portable power stations from 10 brands: ALLPOWERS, Anker SOLIX, Bluetti, DJI Power, EcoFlow, Goal Zero, Jackery, OUPES, Pecron, VTOMAN. We list models we found for sale on each brand's official US online store. This is not every power station on the market. Some listed models have no spec record yet, usually because the manufacturer publishes its spec sheet only as an image, or because one page mixes two variants.

Where specifications come from

  • Only the manufacturer's own website: product pages, spec tables, support pages and user manuals hosted by the manufacturer. We do not use retailer listings, marketplaces, review sites or forums.
  • Every value on a model page links to the exact page or manual it came from and shows the date we checked it. We also keep the exact wording we copied, which you can see by hovering the source link.
  • If the official pages do not state a value, or state it ambiguously, we show "Not confirmed". We never estimate or fill gaps from other sources.
  • If two official pages disagree, we use the spec table or manual and record the conflict internally. If even the spec sources disagree, or the spec table itself is ambiguous, we leave the value blank.
  • "Pending verification" means the manufacturer's own pages give conflicting values for a field that matters, and we are waiting for a definitive official source. The reason is shown next to the field.
  • Spec values were checked between 2026-11-21 and 2026-11-21.

How we read some specs

  • AC output (continuous) is the US model's rated continuous output at 120V. Where a manufacturer lists a separate 120V rating, we use it. Where it gives only one combined rating for a unit whose 120V and 240V outlets share the same inverter, we use that combined figure and say so in our notes. "Boost" modes that only work with resistive loads (X-Boost, Lifting Power, Boost Mode, SurgePad and similar) are never counted.
  • AC surge / peak is the short-term peak a station can deliver at 120V to start motors and compressors. A boost mode that lets heating devices run above the rated output is not a surge rating, so if a manufacturer's only "surge" figure is that boost figure, we leave surge blank. If the only surge figure stated is for 240V output, the 120V surge is left blank.
  • AC charging power is the maximum wall-charging power at 120V input. If a model can also charge faster from a 240V supply, that figure is recorded separately.
  • Where official pages disagree and we take the value from the spec sheet or manual, the model page shows a short note saying what each source says, for example "The product title says 1024 Wh; the US spec sheet says 1070 Wh (30.4Ah/35.2V). We use the spec sheet."
  • Dual-voltage models: 240V ratings are recorded separately, shown as "(240V: X W)" next to the 120V value, and listed below. They are not used in the table, sorting or calculators, because most US appliances run on 120V.
  • Cycles are shown only when the manufacturer states cycles to 80% capacity. Many brands state cycles to 70%; those are left blank so the column compares like with like.
  • UPS / EPS switchover: "under 10 ms" is shown as ≤ 10 ms. Where a model has several modes, we use the factory default.
  • Warranty is the longest period the manufacturer states. It may require registering the product or buying from the official store.
  • Charge time is shown only when stated in minutes for AC charging from 0 to 100%.
  • Max capacity with expansion is shown only when stated as an exact figure for one unit.
  • Pounds and inches are converted to kilograms (× 0.45359237) and millimetres (× 25.4) only when the manufacturer gives no metric figure.

Dual-voltage models (240V ratings)

Models with separately stated 240V output or 240V charging figures. The 120V figure is the one used in the table, sorting and calculators.

ModelContinuous (120V)Surge (120V)Continuous (240V)Surge (240V)AC charging (120V)AC charging (240V)
Anker SOLIX F3800 Plus 6,000 W 9,000 W (240V: 6,000 W) — 1,800 W —
Anker SOLIX S5000 4,500 W 8,000 W (240V: 4,500 W) — 4,500 W —
EcoFlow DELTA Pro 3,600 W 7,200 W — — 1,800 W (240V: 3,000 W)
Jackery Explorer 5000 Plus 7,200 W 14,400 W (240V: 7,200 W) — — —
OUPES Guardian 6000 V2 3,600 W — (240V: 6,000 W) (240V: 9,000 W) 1,800 W (240V: 3,600 W)
Pecron F5000LFP 7,200 W — (240V: 7,200 W) — 3,600 W —

Derived values

  • Wh per kg = capacity ÷ weight.
  • Price per Wh = price ÷ capacity. Prices are not shown yet because we have not connected any merchant price feed. When we do, each price will show the merchant and the time it was last updated, and prices older than 48 hours will be hidden.

Calculators

The runtime calculator and the solar recharge calculator show their formulas and default assumptions on the page. Briefly: AC loads are divided by an inverter efficiency of 0.85, DC loads by 0.92, and 90% of rated capacity is treated as usable. Solar input is capped at the station's rated solar input and multiplied by a system efficiency of 0.75. Results are estimates, not measurements.

Calculator checks

We compared both calculators with examples that manufacturers publish on their own pages, using the same inputs and our default assumptions. Error = (our result − manufacturer's figure) ÷ manufacturer's figure. Our target is within ±15%. Checked 2026-11-21.

Runtime: 4 of 8 examples within ±15%. Manufacturers use different factors in their own runtime formulas: we found 0.85, 0.9 and 0.9 × 0.85 = 0.765. Our default (0.9 usable × 0.85 inverter = 0.765) matches the most conservative one, so our runtimes are usually shorter than other brands' examples. Bluetti's example also includes 15 W of inverter idle draw; with the optional idle-draw input set to 15 W, our result is within 2%. We did not change the formula or defaults to match any brand. Fridge examples are not comparable because manufacturers do not state the fridge's average power.

Solar: 13 of 19 examples within ±15%. Our default system efficiency of 0.75 gives charge times close to EcoFlow's and Jackery Explorer 1500 Ultra's figures (within ±8%), slightly slower than Goal Zero's, and much slower than Jackery Explorer 1500 v2's (its figures imply over 95% efficiency). Goal Zero's Yeti 1000 page gives two different times for 900 W (2 h and 3 h).

Example (manufacturer's words)ModelOfficialOursError
"606 Wh * 0.85 / 66w=8.5 hours" ALLPOWERS S700 (runtime) 8.5 h 7.02 h -17.4% ✗
"606 Wh * 0.9 / 66w=9 hours" ALLPOWERS S700 (runtime) 9 h 7.02 h -22.0% ✗
"1451Wh * 85% / 120W ≈ 10.28 hours" ALLPOWERS S2000 Pro (runtime) 10.28 h 9.25 h -10.0%
"1152Wh × 90% × 85% ÷ (100W+15W) ≈ 7.66 hrs" Bluetti AC180 (runtime) 7.66 h 8.81 h +15.0% ✗
"1152Wh × 90% × 85% ÷ (100W+15W) ≈ 7.66 hrs" (with 15 W idle draw) Bluetti AC180 (runtime) 7.66 h 7.82 h +2.0%
"293Wh*0.85/30w=8.3hrs" Jackery Explorer 300 (runtime) 8.3 h 7.47 h -10.0%
"a wall-mounted AC unit (900W) can run for about 4.5 hours" Jackery Explorer 5000 Plus (runtime) 4.5 h 4.28 h -4.8%
"A compact refrigerator (90W) can operate for about 26 hours" Jackery Explorer 5000 Plus (runtime) 26 h 42.84 h +64.8% ✗
"Fully charged with 400W solar panel in approx. 6.4 hours" EcoFlow DELTA 3 Max Plus (solar) 6.4 h 6.83 h +6.7%
"Solar charge in ~9.6 hrs with 400W panel" EcoFlow DELTA 3000 Gen4 (solar) 9.6 h 10.24 h +6.7%
"Solar charge in ~12 hrs with 320W panel" EcoFlow DELTA 3000 Gen4 (solar) 12 h 12.8 h +6.7%
"Solar charge in ~11.7 hrs with 400W panel" EcoFlow DELTA 3800 Gen4 (solar) 11.7 h 12.54 h +7.2%
"Solar charge in ~15 hrs with 320W panel" EcoFlow DELTA 3800 Gen4 (solar) 15 h 15.68 h +4.5%
"Solar charge in ~7.5 hrs with 640W panel" EcoFlow DELTA 3800 Gen4 (solar) 7.5 h 7.84 h +4.5%
"100W Solar Input (Boulder/Nomad 100): 11.7 hrs" Goal Zero Yeti 1000 (solar) 11.7 h 13.31 h +13.8%
"200W Solar Input (Boulder/Nomad 200): 5.9 hrs" Goal Zero Yeti 1000 (solar) 5.9 h 6.66 h +12.8%
"300W Solar Input (Ranger 300): 3.9 hrs" Goal Zero Yeti 1000 (solar) 3.9 h 4.44 h +13.8%
"400W Solar Input (Nomad 400): 2.9 hrs" Goal Zero Yeti 1000 (solar) 2.9 h 3.33 h +14.8%
"Solar Input Max 900W: 3 hrs" Goal Zero Yeti 1000 (solar) 3 h 1.48 h -50.7% ✗
"900W = 2 Hours" Goal Zero Yeti 1000 (solar) 2 h 1.48 h -26.0% ✗
"100W Solar Input (Boulder/Nomad 100): 17.2 hrs" Goal Zero Yeti 1500 (solar) 17.2 h 20.07 h +16.7% ✗
"200W Solar Input (Boulder/Nomad 200): 8.6 hrs" Goal Zero Yeti 1500 (solar) 8.6 h 10.04 h +16.7% ✗
"4×200W: ~2.7h" Jackery Explorer 1500 Ultra (solar) 2.7 h 2.56 h -5.2%
"2×200W: ~5.5h" Jackery Explorer 1500 Ultra (solar) 5.5 h 5.12 h -6.9%
"1×200W: ~11h" Jackery Explorer 1500 Ultra (solar) 11 h 10.24 h -6.9%
"Solar Charging (400W): 4Hrs" Jackery Explorer 1500 v2 (solar) 4 h 5.12 h +28.0% ✗
"Solar Charging (200W): 7.5Hrs" Jackery Explorer 1500 v2 (solar) 7.5 h 10.24 h +36.5% ✗

Solar peak-sun-hour presets come from the NLR (formerly NREL) Solar Resource Data API: annual average global horizontal irradiance for one city per state, 1998–2009 satellite model data.

Corrections

If you find a value that does not match the manufacturer's official page, email [email protected] with the model and a link to the official source. Changes to published data are listed on the corrections page.